#!/bin/sh /etc/rc.common
START=98

boot() {
	#ceate folder
	[ -d /tmp/modbus_data/ ] || mkdir /tmp/modbus_data/
	# off signal and network leds
	#echo 0 > /sys/class/leds/e220:orange:network/brightness
	#echo 0 >  /sys/class/leds/e220:orange:signal/brightness
	#killall modbusmaster
	stop
	#restart mysql server
	#/etc/init.d/mysql restart
	if  [[ ! `ls /etc/MODBUS_Configuration_E225.csv` ]] || [[ "`ls -l /etc/MODBUS_Configuration_E225.csv  | awk '{print$5}'`" == 0 ]]; then exit ; fi;
	#start modbus app without deleting Database
if [ "`uci get modbus_master.@modbus_master[0].enable 2>/dev/null`" == 1 ]; then
	echo -e "0020,`date +%Y%m%d%H%M%S`,\r" >> /etc/MODBUS_ECO_Err_Events.csv
		##sim card detection
		imsi=`sendat /dev/ttyACM0 AT+CIMI 1 | grep -v [a-zA-Z] | grep [0-9]`
		if [ `expr length "$imsi"` -lt 15 ]; then
			echo -e "2003,`date +%Y%m%d%H%M%S`,\r" >> /etc/MODBUS_ECO_Err_Events.csv
		fi
		#kill serial app
		kill_serial
		database_size=`uci get modbus_master.@modbus_master[0].database_size`
		if [ $database_size ]; then
			/usr/bin/modbusmaster -W -S $database_size &> /dev/null &
		else
			/usr/bin/modbusmaster -W &> /dev/null &
		fi
	fi
}

start() {
	#kill serial app
	kill_serial
	#start modbus app
	if [ $1 == "default_config_file" ]; then
		touch /etc/config_file_upload_flag	2>/dev/null
		database_size=`uci get modbus_master.@modbus_master[0].database_size`
		if [ $database_size ]; then
			/usr/bin/modbusmaster -P -A 1 -S $database_size &> /dev/null &
		else
			/usr/bin/modbusmaster -P -A 1 &> /dev/null &
		fi
	else
		rm -r /etc/config_file_upload_flag	2>/dev/null
		database_size=`uci get modbus_master.@modbus_master[0].database_size`
		if [ $database_size ]; then
			/usr/bin/modbusmaster -P -A 0 -S $database_size &> /dev/null &
		else
			/usr/bin/modbusmaster -P -A 0 &> /dev/null &
		fi
	fi
        ##/usr/bin/modbusmaster -P &> /dev/null &
    }

    stop() {
    #killall modbusmaster
    #ps | grep -i modbusmaster | grep -v grep | awk '{print $1}' | xargs kill -9
    #ps | grep -i /usr/sbin/Eco_fargo_converter.sh | grep -v grep | awk '{print $1}' | xargs kill -9
    killall modbusmaster 2>/dev/null
    return 0
}
reload() {
	#ceate folder
	[ -d /tmp/modbus_data/ ] || mkdir /tmp/modbus_data/
	stop
	#kill serial app
	if [ "`uci get modbus_master.@modbus_master[0].enable 2>/dev/null`" == 1 ]; then
		kill_serial
		#start modbus app without deleting Database
		database_size=`uci get modbus_master.@modbus_master[0].database_size`
		if [ $database_size ]; then
			/usr/bin/modbusmaster -W -S $database_size &> /dev/null &
		else
			/usr/bin/modbusmaster -W &> /dev/null &
		fi
	fi
}
restart() {
	#ceate folder
	[ -d /tmp/modbus_data/ ] || mkdir /tmp/modbus_data/
	# off signal and network leds
	#echo 0 > /sys/class/leds/e220:orange:network/brightness
	#echo 0 >  /sys/class/leds/e220:orange:signal/brightness

	if [ "$1" == "reconfiguration_and_restart" ]; then
		stop
		echo -e "0035,`date +%Y%m%d%H%M%S`,\r" >> /etc/MODBUS_ECO_Err_Events.csv
		start "default_config_file"
	else
		stop
	#start modbus app 
	if [ "`uci get modbus_master.@modbus_master[0].enable 2>/dev/null`" == 1 ]; then
		##delete previous config file
		rm /etc/MODBUS_Configuration_E225.csv 
		#rm /etc/Eco_axis_MODBUS_Configuration_E225.csv
		rm /etc/MODBUS_ECO_Err_Events*
		rm /etc/MODBUS_fargo_Err_Events.csv
		rm /tmp/modbus_data/modbus_status
		rm /tmp/modbus_data/PID_OF_MODBUS
		#copy config file
		cp "`uci get modbus_master.@modbus_master[0].config_file`" /etc/MODBUS_Configuration_E225.csv
		#echo 'Starting Configuration file Conversion.........' > /tmp/modbus_data/modbus_status
		##convert Eco Axis file into fargo config file
		#/usr/sbin/Eco_fargo_converter.sh /etc/Eco_axis_MODBUS_Configuration_E225.csv /etc/MODBUS_Configuration_E225.csv
		if  [[ ! `ls /etc/MODBUS_Configuration_E225.csv` ]] || [[ "`ls -l /etc/MODBUS_Configuration_E225.csv  | awk '{print$5}'`" == 0 ]]; then 
			echo 'Configuration File Not Found' > /tmp/modbus_data/modbus_status
			exit 
		fi
		#echo 'Configuration file Conversion completed' > /tmp/modbus_data/modbus_status

		echo -e "0034,`date +%Y%m%d%H%M%S`,\r" >> /etc/MODBUS_ECO_Err_Events.csv
		echo -e "0035,`date +%Y%m%d%H%M%S`,\r" >> /etc/MODBUS_ECO_Err_Events.csv
		start "default_config_file"
	else
		##delete previous config file
		rm /etc/MODBUS_Configuration_E225.csv
		rm "`uci get modbus_master.@modbus_master[0].config_file`"
		#rm /etc/Eco_axis_MODBUS_Configuration_E225.csv
		rm /tmp/modbus_data/modbus_status
		db_delete
	fi	
fi	
}
db_delete() {
	#Delete Existing database
	/usr/bin/modbusmaster -D &> /dev/null &
}
# kill the serial application that used serial port
kill_serial() {
	check_serial=`ps | grep -i serial | grep -v grep | awk '{print $1}'`
	if [ "$check_serial" != "" ]; then
		ps | grep -i serial.sh | grep -v grep | awk '{print $1}' | xargs kill
		killall serial
	fi
	# Disable serial application
	serial_enable=`uci get serial.@datasendconfiguration[0].serial_enable`
	if [ $serial_enable == 1 ]; then
		uci set serial.@datasendconfiguration[0].serial_enable=0
		uci commit
	fi
}
reconfiguration_and_restart() {
	start
}